work: исправил архитектуру управления температурой. Теперь отдельный контроллер отвечает за нагрев для всех режимов авто ручной или временный ручной. Раньше в каждом режиме была своя логика.

This commit is contained in:
2026-09-29 22:49:31 +03:00
parent ba8151305a
commit 2a7d2a0b8b
41 changed files with 1632 additions and 2768 deletions
@@ -0,0 +1,425 @@
import asyncio
import os
import paho.mqtt.client as mqtt
from app.auto.config import load_auto_config
from app.auto.controller import AutoController
from app.auto.elica_assist import ElicaAutoAssistState
from app.elica import (
ElicaConfig,
ElicaController,
ElicaService,
)
from app.my_dataclasses import (
ELICA_MQTT_HOST,
ELICA_MQTT_PORT,
)
AUTO_CONFIG = "config/auto.yaml"
ELICA_READY_TIMEOUT = 15.0
class TestElicaService(ElicaService):
async def start(self) -> None:
if self._running:
return
client_id = (
f"climatcontroller-auto-elica-already-on-test-"
f"{os.getpid()}"
)
print(
"Test MQTT client_id:",
client_id,
)
client = mqtt.Client(
callback_api_version=(
mqtt.CallbackAPIVersion.VERSION2
),
client_id=client_id,
)
client.on_connect = self._on_connect
client.on_disconnect = self._on_disconnect
client.on_message = self._on_message
client.reconnect_delay_set(
min_delay=1,
max_delay=30,
)
self._client = client
self._running = True
client.connect_async(
self._config.mqtt_host,
self._config.mqtt_port,
keepalive=60,
)
client.loop_start()
async def wait_for_elica(
service: ElicaService,
) -> None:
loop = asyncio.get_running_loop()
deadline = (
loop.time()
+ ELICA_READY_TIMEOUT
)
while True:
state = service.state
if (
state.mqtt_connected
and state.device_online
and service.feedback_ready
):
return
if loop.time() >= deadline:
raise RuntimeError(
"Elica did not become ready.\n"
f"mqtt_connected="
f"{state.mqtt_connected}\n"
f"device_online="
f"{state.device_online}\n"
f"feedback_ready="
f"{service.feedback_ready}\n"
f"missing_feedback_inputs="
f"{service.missing_feedback_inputs}"
)
await asyncio.sleep(0.1)
async def main() -> None:
service = TestElicaService(
ElicaConfig(
mqtt_host=ELICA_MQTT_HOST,
mqtt_port=ELICA_MQTT_PORT,
)
)
elica_controller = ElicaController(
service
)
print(
"Starting Elica service..."
)
await service.start()
try:
print(
f"Connecting to MQTT "
f"{ELICA_MQTT_HOST}:"
f"{ELICA_MQTT_PORT}..."
)
await wait_for_elica(
service
)
print(
"Elica connected and "
"feedback ready"
)
initial = elica_controller.state
print()
print(
"Initial Elica:",
{
"power": initial.power,
"speed": initial.speed,
"timer": initial.timer,
},
)
# --------------------------------------------------
# Для этого теста Elica должна быть заранее
# включена пользователем.
# --------------------------------------------------
if not initial.power:
raise RuntimeError(
"Before starting this test, "
"manually turn Elica ON "
"at any speed."
)
initial_power = initial.power
initial_speed = initial.speed
initial_timer = initial.timer
config = load_auto_config(
AUTO_CONFIG
)
assist = ElicaAutoAssistState(
config.elica_assist
)
auto_controller = AutoController(
schedule_service=object(),
qingping_service=object(),
tion_service=object(),
elica_controller=elica_controller,
policy=None,
temperature_policy=None,
elica_assist=assist,
interval=1.0,
)
# ==================================================
# ЭТАП 1
#
# Пользовательская Elica уже включена.
#
# Tion AUTO поднимается до 4.
#
# AutoController должен:
#
# увидеть Elica ON
# -> SUPPRESSED
# -> reason = elica_already_on
# -> ничего не переключать
# ==================================================
print()
print(
"STEP 1:"
)
print(
"Tion AUTO speed 4 while "
"Elica is already user-controlled."
)
await auto_controller._update_elica_assist(
4
)
after_speed_4 = elica_controller.state
print()
print(
"Elica after Tion speed 4:",
{
"power": after_speed_4.power,
"speed": after_speed_4.speed,
"timer": after_speed_4.timer,
},
)
print(
"Assist:",
assist.status(),
)
if assist.mode.value != "suppressed":
raise RuntimeError(
"Assist did not enter SUPPRESSED"
)
if (
assist.status()["reason"]
!= "elica_already_on"
):
raise RuntimeError(
"Expected reason elica_already_on"
)
# --------------------------------------------------
# Elica обязана остаться полностью неизменной.
# --------------------------------------------------
if (
after_speed_4.power != initial_power
or after_speed_4.speed != initial_speed
or after_speed_4.timer != initial_timer
):
raise RuntimeError(
"AutoController modified "
"already-running user Elica"
)
print()
print(
"SUPPRESSION PASSED"
)
# ==================================================
# ЭТАП 2
#
# Пока Tion остаётся в диапазоне,
# например поднимается 4 -> 5.
#
# Elica всё равно трогать нельзя.
# ==================================================
print()
print(
"STEP 2:"
)
print(
"Tion AUTO speed changes 4 -> 5."
)
print(
"Elica must remain untouched."
)
await auto_controller._update_elica_assist(
5
)
after_speed_5 = elica_controller.state
print()
print(
"Elica after Tion speed 5:",
{
"power": after_speed_5.power,
"speed": after_speed_5.speed,
"timer": after_speed_5.timer,
},
)
print(
"Assist:",
assist.status(),
)
if assist.mode.value != "suppressed":
raise RuntimeError(
"Assist left SUPPRESSED "
"during the same cycle"
)
if (
after_speed_5.power != initial_power
or after_speed_5.speed != initial_speed
or after_speed_5.timer != initial_timer
):
raise RuntimeError(
"AutoController modified Elica "
"while SUPPRESSED"
)
print()
print(
"SUPPRESSED HOLD PASSED"
)
# ==================================================
# ЭТАП 3
#
# Tion падает до 3.
#
# Текущий повышенный AUTO-цикл закончен.
#
# Elica должна остаться пользовательской,
# но Assist может вернуться в IDLE.
# ==================================================
print()
print("STEP 3:")
print("Tion AUTO speed drops to 3.")
print(
"Elica must remain ON and unchanged."
)
await auto_controller._update_elica_assist(
3
)
final_elica = elica_controller.state
print()
print(
"Final Elica:",
{
"power": final_elica.power,
"speed": final_elica.speed,
"timer": final_elica.timer,
},
)
print(
"Final Assist:",
assist.status(),
)
if (
final_elica.power != initial_power
or final_elica.speed != initial_speed
or final_elica.timer != initial_timer
):
raise RuntimeError(
"AutoController changed user Elica "
"when the Tion cycle ended"
)
if assist.mode.value != "idle":
raise RuntimeError(
"Assist did not return to IDLE "
"after Tion dropped below threshold"
)
print()
print(
"CYCLE END PASSED"
)
print()
print(
"TEST PASSED"
)
print()
print("Verified sequence:")
print(
"User Elica already ON"
" -> Tion 4"
" -> SUPPRESSED"
)
print(
"Tion 5"
" -> Elica untouched"
" -> still SUPPRESSED"
)
print(
"Tion 3"
" -> Elica untouched"
" -> IDLE"
)
finally:
print()
print("Stopping Elica service...")
await service.stop()
if __name__ == "__main__":