work: Изменил конфиг сервиса вытяжки для реальной платы. Добавил yaml конфигурацию платы. Сейчас доступны MQTT -прием статуса и управление реле.
This commit is contained in:
@@ -0,0 +1,278 @@
|
||||
esphome:
|
||||
name: elica-relay
|
||||
friendly_name: Elica Relay Controller
|
||||
on_boot:
|
||||
# First disable 74HC595 outputs so relays cannot chatter during boot.
|
||||
- priority: 900
|
||||
then:
|
||||
- lambda: |-
|
||||
pinMode(13, OUTPUT);
|
||||
digitalWrite(13, HIGH);
|
||||
|
||||
# Initialise shared bus, force all relays OFF, then enable outputs.
|
||||
- priority: 600
|
||||
then:
|
||||
- delay: 500ms
|
||||
- lambda: |-
|
||||
pinMode(25, OUTPUT); // shared LATCH
|
||||
pinMode(26, OUTPUT); // shared CLOCK
|
||||
pinMode(33, OUTPUT); // data to 74HC595
|
||||
pinMode(27, INPUT); // data from 74HC165
|
||||
|
||||
digitalWrite(25, LOW);
|
||||
shiftOut(33, 26, MSBFIRST, 0xFF); // active-low relays: all OFF
|
||||
digitalWrite(25, HIGH);
|
||||
|
||||
id(relay_state) = 0x00;
|
||||
digitalWrite(13, LOW); // enable 74HC595 outputs
|
||||
|
||||
esp32:
|
||||
board: esp32dev
|
||||
framework:
|
||||
type: arduino
|
||||
|
||||
logger:
|
||||
|
||||
wifi:
|
||||
ssid: !secret wifi_ssid
|
||||
password: !secret wifi_password
|
||||
|
||||
ap:
|
||||
ssid: "Elica-Relay-Fallback"
|
||||
password: !secret fallback_password
|
||||
|
||||
captive_portal:
|
||||
|
||||
# We use MQTT as the main connection to the controller.
|
||||
# Home Assistant / native ESPHome API is deliberately not enabled.
|
||||
mqtt:
|
||||
broker: !secret mqtt_broker
|
||||
username: !secret mqtt_username
|
||||
password: !secret mqtt_password
|
||||
discovery: false
|
||||
|
||||
birth_message:
|
||||
topic: elica/status
|
||||
payload: online
|
||||
retain: true
|
||||
|
||||
will_message:
|
||||
topic: elica/status
|
||||
payload: offline
|
||||
retain: true
|
||||
|
||||
ota:
|
||||
- platform: esphome
|
||||
password: !secret ota_password
|
||||
|
||||
# Handy while commissioning the board.
|
||||
web_server:
|
||||
port: 80
|
||||
|
||||
globals:
|
||||
- id: relay_state
|
||||
type: uint8_t
|
||||
restore_value: no
|
||||
initial_value: '0x00'
|
||||
|
||||
- id: input_state
|
||||
type: uint8_t
|
||||
restore_value: no
|
||||
initial_value: '0xFF'
|
||||
|
||||
script:
|
||||
- id: write_relays
|
||||
mode: restart
|
||||
then:
|
||||
- lambda: |-
|
||||
// Relay drivers are active LOW.
|
||||
digitalWrite(25, LOW);
|
||||
shiftOut(33, 26, MSBFIRST, ~id(relay_state));
|
||||
digitalWrite(25, HIGH);
|
||||
|
||||
# 74HC595 and 74HC165 share CLOCK/LATCH on this board.
|
||||
# Read inputs, then immediately restore the relay register.
|
||||
interval:
|
||||
- interval: 100ms
|
||||
then:
|
||||
- lambda: |-
|
||||
// Parallel-load current input state into 74HC165.
|
||||
digitalWrite(25, LOW);
|
||||
delayMicroseconds(10);
|
||||
digitalWrite(25, HIGH);
|
||||
|
||||
uint8_t v = 0;
|
||||
for (int i = 0; i < 8; i++) {
|
||||
v <<= 1;
|
||||
if (digitalRead(27)) v |= 1;
|
||||
|
||||
digitalWrite(26, HIGH);
|
||||
delayMicroseconds(2);
|
||||
digitalWrite(26, LOW);
|
||||
delayMicroseconds(2);
|
||||
}
|
||||
|
||||
id(input_state) = v;
|
||||
|
||||
// Shared bus changed while reading 74HC165:
|
||||
// restore the requested relay state in 74HC595.
|
||||
digitalWrite(25, LOW);
|
||||
shiftOut(33, 26, MSBFIRST, ~id(relay_state));
|
||||
digitalWrite(25, HIGH);
|
||||
|
||||
switch:
|
||||
- platform: template
|
||||
name: "Relay 1"
|
||||
id: relay1
|
||||
restore_mode: ALWAYS_OFF
|
||||
lambda: return (id(relay_state) & 0x01) != 0;
|
||||
turn_on_action:
|
||||
- lambda: id(relay_state) |= 0x01;
|
||||
- script.execute: write_relays
|
||||
turn_off_action:
|
||||
- lambda: id(relay_state) &= ~0x01;
|
||||
- script.execute: write_relays
|
||||
command_topic: "elica/relay/1/set"
|
||||
state_topic: "elica/relay/1/state"
|
||||
|
||||
- platform: template
|
||||
name: "Relay 2"
|
||||
id: relay2
|
||||
restore_mode: ALWAYS_OFF
|
||||
lambda: return (id(relay_state) & 0x02) != 0;
|
||||
turn_on_action:
|
||||
- lambda: id(relay_state) |= 0x02;
|
||||
- script.execute: write_relays
|
||||
turn_off_action:
|
||||
- lambda: id(relay_state) &= ~0x02;
|
||||
- script.execute: write_relays
|
||||
command_topic: "elica/relay/2/set"
|
||||
state_topic: "elica/relay/2/state"
|
||||
|
||||
- platform: template
|
||||
name: "Relay 3"
|
||||
id: relay3
|
||||
restore_mode: ALWAYS_OFF
|
||||
lambda: return (id(relay_state) & 0x04) != 0;
|
||||
turn_on_action:
|
||||
- lambda: id(relay_state) |= 0x04;
|
||||
- script.execute: write_relays
|
||||
turn_off_action:
|
||||
- lambda: id(relay_state) &= ~0x04;
|
||||
- script.execute: write_relays
|
||||
command_topic: "elica/relay/3/set"
|
||||
state_topic: "elica/relay/3/state"
|
||||
|
||||
- platform: template
|
||||
name: "Relay 4"
|
||||
id: relay4
|
||||
restore_mode: ALWAYS_OFF
|
||||
lambda: return (id(relay_state) & 0x08) != 0;
|
||||
turn_on_action:
|
||||
- lambda: id(relay_state) |= 0x08;
|
||||
- script.execute: write_relays
|
||||
turn_off_action:
|
||||
- lambda: id(relay_state) &= ~0x08;
|
||||
- script.execute: write_relays
|
||||
command_topic: "elica/relay/4/set"
|
||||
state_topic: "elica/relay/4/state"
|
||||
|
||||
- platform: template
|
||||
name: "Relay 5"
|
||||
id: relay5
|
||||
restore_mode: ALWAYS_OFF
|
||||
lambda: return (id(relay_state) & 0x10) != 0;
|
||||
turn_on_action:
|
||||
- lambda: id(relay_state) |= 0x10;
|
||||
- script.execute: write_relays
|
||||
turn_off_action:
|
||||
- lambda: id(relay_state) &= ~0x10;
|
||||
- script.execute: write_relays
|
||||
command_topic: "elica/relay/5/set"
|
||||
state_topic: "elica/relay/5/state"
|
||||
|
||||
- platform: template
|
||||
name: "Relay 6"
|
||||
id: relay6
|
||||
restore_mode: ALWAYS_OFF
|
||||
lambda: return (id(relay_state) & 0x20) != 0;
|
||||
turn_on_action:
|
||||
- lambda: id(relay_state) |= 0x20;
|
||||
- script.execute: write_relays
|
||||
turn_off_action:
|
||||
- lambda: id(relay_state) &= ~0x20;
|
||||
- script.execute: write_relays
|
||||
command_topic: "elica/relay/6/set"
|
||||
state_topic: "elica/relay/6/state"
|
||||
|
||||
- platform: template
|
||||
name: "Relay 7"
|
||||
id: relay7
|
||||
restore_mode: ALWAYS_OFF
|
||||
lambda: return (id(relay_state) & 0x40) != 0;
|
||||
turn_on_action:
|
||||
- lambda: id(relay_state) |= 0x40;
|
||||
- script.execute: write_relays
|
||||
turn_off_action:
|
||||
- lambda: id(relay_state) &= ~0x40;
|
||||
- script.execute: write_relays
|
||||
command_topic: "elica/relay/7/set"
|
||||
state_topic: "elica/relay/7/state"
|
||||
|
||||
- platform: template
|
||||
name: "Relay 8"
|
||||
id: relay8
|
||||
restore_mode: ALWAYS_OFF
|
||||
lambda: return (id(relay_state) & 0x80) != 0;
|
||||
turn_on_action:
|
||||
- lambda: id(relay_state) |= 0x80;
|
||||
- script.execute: write_relays
|
||||
turn_off_action:
|
||||
- lambda: id(relay_state) &= ~0x80;
|
||||
- script.execute: write_relays
|
||||
command_topic: "elica/relay/8/set"
|
||||
state_topic: "elica/relay/8/state"
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "Input 1"
|
||||
lambda: return !(id(input_state) & 0x10);
|
||||
state_topic: "elica/input/1/state"
|
||||
|
||||
- platform: template
|
||||
name: "Input 2"
|
||||
lambda: return !(id(input_state) & 0x08);
|
||||
state_topic: "elica/input/2/state"
|
||||
|
||||
- platform: template
|
||||
name: "Input 3"
|
||||
lambda: return !(id(input_state) & 0x20);
|
||||
state_topic: "elica/input/3/state"
|
||||
|
||||
- platform: template
|
||||
name: "Input 4"
|
||||
lambda: return !(id(input_state) & 0x04);
|
||||
state_topic: "elica/input/4/state"
|
||||
|
||||
- platform: template
|
||||
name: "Input 5"
|
||||
lambda: return !(id(input_state) & 0x40);
|
||||
state_topic: "elica/input/5/state"
|
||||
|
||||
- platform: template
|
||||
name: "Input 6"
|
||||
lambda: return !(id(input_state) & 0x02);
|
||||
state_topic: "elica/input/6/state"
|
||||
|
||||
- platform: template
|
||||
name: "Input 7"
|
||||
lambda: return !(id(input_state) & 0x80);
|
||||
state_topic: "elica/input/7/state"
|
||||
|
||||
- platform: template
|
||||
name: "Input 8"
|
||||
lambda: return !(id(input_state) & 0x01);
|
||||
state_topic: "elica/input/8/state"
|
||||
|
||||
- platform: status
|
||||
name: "Controller Status"
|
||||
@@ -0,0 +1,28 @@
|
||||
ELICA ESP32 RELAY X8 - INITIAL COMMISSIONING
|
||||
|
||||
Files:
|
||||
elica-relay.yaml Main ESPHome configuration
|
||||
secrets.yaml.template Copy/rename this to secrets.yaml and enter your values
|
||||
|
||||
Target hardware:
|
||||
LCTech ESP32 Relay Board X8 Modbus / 303e32dc812
|
||||
ESP32-WROOM-32E
|
||||
74HC595 relay outputs + 74HC165 optocoupled inputs on shared bus
|
||||
|
||||
First commissioning:
|
||||
1. Install ESPHome Device Builder.
|
||||
2. Put elica-relay.yaml and secrets.yaml in its config folder/project.
|
||||
3. Connect the board by USB-C.
|
||||
4. Compile and install via USB.
|
||||
5. After boot, supply the board from a suitable 9-24 V DC power supply for relay/input tests.
|
||||
6. Test all relays before connecting anything to Elica.
|
||||
|
||||
MQTT topics:
|
||||
elica/status
|
||||
elica/relay/1/set ... elica/relay/8/set
|
||||
elica/relay/1/state ... elica/relay/8/state
|
||||
elica/input/1/state ... elica/input/8/state
|
||||
|
||||
Relay commands use ON / OFF.
|
||||
All relays are forced OFF during boot.
|
||||
Inputs do not control relays.
|
||||
@@ -0,0 +1,15 @@
|
||||
# Fill these values before compiling.
|
||||
|
||||
wifi_ssid: "YOUR_WIFI_SSID"
|
||||
wifi_password: "YOUR_WIFI_PASSWORD"
|
||||
|
||||
# IP address or DNS name of the existing Mosquitto broker.
|
||||
mqtt_broker: "192.168.1.10"
|
||||
mqtt_username: "YOUR_MQTT_USERNAME"
|
||||
mqtt_password: "YOUR_MQTT_PASSWORD"
|
||||
|
||||
# Used only if normal Wi-Fi cannot be reached.
|
||||
fallback_password: "ChangeMe123!"
|
||||
|
||||
# Password for future wireless firmware updates.
|
||||
ota_password: "ChangeThisOTAPassword"
|
||||
Reference in New Issue