work: функционал для работы с вятяжкой

* Добавил полный функционал управления elica через esp32 по MQTT
* Добавил в прошивку принудительную блокировку внешнего винтелятора при работающей вытяжке
* Добавил веб-панели для управления вытяжкой
This commit is contained in:
2026-09-26 23:59:01 +03:00
parent 3b3c7a3f13
commit bf832ac86b
12 changed files with 631 additions and 52 deletions
+71 -1
View File
@@ -80,6 +80,18 @@ globals:
restore_value: no
initial_value: '0xFF'
# Tracks the real Elica Power LED so OUT5 can be used as a hard
# interlock for the external fan. The LED line is active LOW.
- id: elica_power_initialized
type: bool
restore_value: no
initial_value: 'false'
- id: elica_power_was_on
type: bool
restore_value: no
initial_value: 'false'
script:
- id: write_relays
mode: restart
@@ -114,12 +126,53 @@ interval:
id(input_state) = v;
// Elica Power LED is connected to IN5 (74HC165 mask 0x40).
// IMPORTANT: on this board the 74HC165 raw state is inverted
// relative to the MQTT binary_sensor state. Empirically:
// raw bit 1 -> Elica Power LED ON, raw bit 0 -> LED OFF.
const bool elica_power_on = (v & 0x40) != 0;
bool relay5_changed = false;
if (!id(elica_power_initialized)) {
id(elica_power_initialized) = true;
// If ESP32 boots while Elica is already running, enforce
// the interlock immediately. If Elica is OFF, boot defaults
// already leave Relay 5 OFF -> NC closed -> fan ON.
if (elica_power_on && !(id(relay_state) & 0x10)) {
id(relay_state) |= 0x10;
relay5_changed = true;
}
} else if (elica_power_on) {
// Hard interlock: while Elica is ON, Relay 5 must stay ON.
// Relay 5 ON opens the NC contact and stops the external fan.
if (!(id(relay_state) & 0x10)) {
id(relay_state) |= 0x10;
relay5_changed = true;
}
} else if (id(elica_power_was_on)) {
// Elica has just switched OFF: automatically restore the
// external fan. Relay 5 OFF closes NC and starts the fan.
if (id(relay_state) & 0x10) {
id(relay_state) &= ~0x10;
relay5_changed = true;
}
}
id(elica_power_was_on) = elica_power_on;
// Shared bus changed while reading 74HC165:
// restore the requested relay state in 74HC595.
digitalWrite(25, LOW);
shiftOut(33, 26, MSBFIRST, ~id(relay_state));
digitalWrite(25, HIGH);
// Keep MQTT/web-server state in sync when the interlock itself
// changes Relay 5 rather than an external command doing it.
if (relay5_changed) {
id(relay5).publish_state((id(relay_state) & 0x10) != 0);
}
switch:
- platform: template
name: "Relay 1"
@@ -177,6 +230,15 @@ switch:
command_topic: "elica/relay/4/set"
state_topic: "elica/relay/4/state"
# OUT5 управляет внешним вентилятором через NC-контакт.
# relay5=OFF -> NC замкнут -> внешний вентилятор ВКЛ.
# relay5=ON -> NC разомкнут -> внешний вентилятор ВЫКЛ.
#
# HARD INTERLOCK по фактическому Power LED Elica (IN5):
# Elica ON -> Relay 5 принудительно ON -> внешний вентилятор OFF.
# Elica OFF -> при переходе автоматически Relay 5 OFF -> вентилятор ON.
# Пока Elica включена, MQTT-команда Relay 5 OFF игнорируется, чтобы
# внешний вентилятор нельзя было случайно включить одновременно с Elica.
- platform: template
name: "Relay 5"
id: relay5
@@ -186,7 +248,15 @@ switch:
- lambda: id(relay_state) |= 0x10;
- script.execute: write_relays
turn_off_action:
- lambda: id(relay_state) &= ~0x10;
- lambda: |-
// Use the same raw IN5 polarity as the interlock above:
// raw bit 1 means the Elica Power LED is ON.
const bool elica_power_on = (id(input_state) & 0x40) != 0;
if (elica_power_on) {
id(relay_state) |= 0x10;
} else {
id(relay_state) &= ~0x10;
}
- script.execute: write_relays
command_topic: "elica/relay/5/set"
state_topic: "elica/relay/5/state"